Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1239734.015
Citation: 01010C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/06/2017
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 01/15/2018
Gravity: 5
Report ID: 0625400
Contest Date:
Final Order: 10/26/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | $0.00 | 01/15/2018 | Serious | ||
Penalty | P: Petition to Mod Abatement | $0.00 | 12/15/2017 | Serious | ||
Penalty | I: Informal Settlement | 10/26/2017 | $0.00 | 11/01/2017 | Serious | |
Penalty | Z: Issued | 09/06/2017 | $0.00 | 09/26/2017 | Serious |
Text For Citation: 01 Item/Group: 010C Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves: On or about July 27, 2017, at the beamline inside conveyor/rack system, the rotating unprotected shaft was projecting out more than half the diameter of the shaft. Employees work and walk by the conveyor with the rotating projected shaft. Employees exposed to the hazard of being caught-in the rotating protruding shaft.