Violation Detail
Standard Cited: 19100184 E03 II Slings.
Inspection Nr: 1303654.015
Citation: 01010B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/10/2018
Nr Instances: 1
Nr Exposed: 25
Abatement Date: 07/30/2018
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 08/01/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/01/2018 | $0.00 | 07/30/2018 | Serious | |
Penalty | Z: Issued | 07/10/2018 | $0.00 | 07/30/2018 | Serious |
Text For Citation: 01 Item/Group: 010B Hazard:
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination: a) Atlantic Precast Concrete - On or about March 20, 2018, employees were utilizing steel chain slings to lift concrete forms with overhead cranes and the employer did not maintain records of when the slings were last thoroughly inspected, exposing employees to stuck-by hazards. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.