Violation Detail
Standard Cited: 19261211 C02
Inspection Nr: 1206035.015
Citation: 01010B
Citation Type: Serious
Abatement Date: 08/11/2017 4
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/20/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0213900
Contest Date: 08/04/2017
Final Order: 12/29/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 12/29/2021 | $0.00 | 08/11/2017 | Serious | |
Penalty | C: Contested | 08/07/2017 | $0.00 | 08/11/2017 | Serious | |
Penalty | Z: Issued | 07/20/2017 | $0.00 | 08/11/2017 | Serious |
Text For Citation: 01 Item/Group: 010B Hazard:
29 CFR 1926.1211(c)(2): The other end of the retrieval line was not attached to a mechanical device or fixed point outside the permit space in such a manner that rescue could begin as soon as the rescuer became aware that rescue was necessary. A mechanical device was not available to retrieve personnel from vertical type permit spaces more than 5 feet (1.52 meters) deep: a) 9000 River Rd, Delair, NJ, 08110- Anodizing: The opposite end of a retrieval line attached to employee's harnesses was not attached to a mechanical device outside of an anodizing tank to allow for immediate rescue when employees were inside of an eight foot deep anodizing tank performing welding, on or about 2/24/2017. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.