Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1287786.015
Citation: 01010A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,174.00
Current Penalty: $2,587.00
Issuance Date: 05/03/2018
Nr Instances: 2
Nr Exposed: 15
Abatement Date: 05/30/2018
Gravity: 5
Report ID: 0626300
Contest Date: 05/30/2018
Final Order: 05/29/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/29/2019 | $2,587.00 | 05/30/2018 | Serious | |
Penalty | C: Contested | 06/04/2018 | $5,174.00 | 05/30/2018 | Serious | |
Penalty | Z: Issued | 05/03/2018 | $5,174.00 | 05/30/2018 | Serious |
Text For Citation: 01 Item/Group: 010A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Outside Curing Oven Area, below the Curing Oven employees were exposed to caught by and amputation hazards while working near the pulley belt wheels. (b) Machine Shop, Rockwell Delta Vertical Belt Sander, where employees were exposed to caught by and amputation hazards when working near the pulley belt wheels.