Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1100641.015
Citation: 01010A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,400.00
Current Penalty: $1,200.00
Issuance Date: 03/10/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/22/2016
Gravity: 5
Report ID: 0316400
Contest Date: 04/04/2016
Final Order: 07/18/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/18/2016 | $1,200.00 | 03/22/2016 | Serious | |
Penalty | C: Contested | 04/07/2016 | $2,400.00 | 03/22/2016 | Serious | |
Penalty | Z: Issued | 03/10/2016 | $2,400.00 | 03/22/2016 | Serious |
Text For Citation: 01 Item/Group: 010A Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end, and projected more than one half the diameter of the shaft: (a) Edger: On or about October 21, 2015, and times prior, an employee operates a 36 inch tower edger and walks back and forth during operation where the unguarded end of the 1.5 inch diameter horizontal rotating shaft projects out 1 1/2 inches and 36 inches above the floor.