Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1091131.015
Citation: 01010A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,300.00
Current Penalty: $3,780.00
Issuance Date: 02/22/2016
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 04/15/2016
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 03/15/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/15/2016 | $3,780.00 | 04/15/2016 | Serious | |
Penalty | Z: Issued | 02/22/2016 | $6,300.00 | 03/17/2016 | Serious |
Text For Citation: 01 Item/Group: 010A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): The employer does not guard all pulleys seven (7) feet or less from the floor or working platform: a) Sawmill building 1 and 3, where employees were not protected from the ingoing nip-point while working near the dust chain without a guard covering the pulley. b) Sawmill building 2, where employees were not protected from the ingoing nip-point while working near the dust chain without a guard covering the pulley.