Violation Detail
Standard Cited: 19100219 P01 Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 940809.015
Citation: 01010
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $0.00
Issuance Date: 11/16/2012
Nr Instances: 3
Nr Exposed: 12
Abatement Date: 12/21/2012
Gravity: 10
Report ID: 0728500
Contest Date: 12/10/2012
Final Order: 02/04/2014
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/04/2014 | $0.00 | 12/21/2012 | Serious | |
Penalty | C: Contested | 09/11/2013 | $2,800.00 | 12/21/2012 | Serious | |
Penalty | Z: Issued | 11/16/2012 | $2,800.00 | 12/21/2012 | Serious |
Text For Citation: 01 Item/Group: 010 Hazard:
29 CFR 1910.219(p)(1): Power transmission equipment was not kept in good working condition: (a) The shaft ends of the transfer roller casing was rubbing on the cover, cutting a hole in the cover in two places and creating a spark and fire hazard; (b) The chain and sprockets on a roller casing was rubbing on the metal cover cutting into the cover and creating a spark and fire hazard; and (c) The cover over the chain and gears on the roller casing coming from the edge saw had sharp edges that created a hazard.