Violation Detail
Standard Cited: 19100179 B05 Overhead and gantry cranes.
Inspection Nr: 1655395.015
Citation: 01010
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,929.00
Current Penalty: $5,000.00
Issuance Date: 09/07/2023
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 10/03/2023
Gravity: 5
Report ID: 0317700
Contest Date: 09/29/2023
Final Order: 05/27/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/27/2024 | $5,000.00 | 10/03/2023 | Serious | |
Penalty | C: Contested | 10/25/2023 | $8,929.00 | 10/03/2023 | Serious | |
Penalty | Z: Issued | 09/07/2023 | $8,929.00 | 10/03/2023 | Serious |
Text For Citation: 01 Item/Group: 010 Hazard:
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane: a) Line #2 Door Station: A Pittsburg hoist that was mounted to an overhead structure and used as an overhead crane was not marked to indicate its maximum load capacity, exposing employees to crushing hazards, on or about March 28, 2023. b) Overhead Crane #7: The Harrington bridge crane in the back of the production area was not marked to indicate its maximum load capacity, exposing employees to crushing hazards, on or about May 2, 2023. ABATEMENT CERTIFICATION REQUIRED