Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1356555.015
Citation: 01010
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,577.00
Current Penalty: $5,500.00
Issuance Date: 04/25/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 05/28/2019
Gravity: 5
Report ID: 0213600
Contest Date: 05/17/2019
Final Order: 11/29/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 11/29/2019 | $5,500.00 | 05/28/2019 | Serious | |
Penalty | C: Contested | 05/20/2019 | $7,577.00 | 05/28/2019 | Serious | |
Penalty | Z: Issued | 04/25/2019 | $7,577.00 | 05/28/2019 | Serious |
Text For Citation: 01 Item/Group: 010 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) On or about 10/30/18 in the Machine room; employees were exposed to crushing injury when the shaft for compressor marked - DPR 9x9 was exposed on either side of the flywheel guard; one near the walkway and the other between the flywheel guard and the oiler device. ABATEMENT CERTIFICATION REQUIRED