Violation Detail
Standard Cited: 19101026 D01
Inspection Nr: 1155212.015
Citation: 01010
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $11,224.00
Current Penalty: $2,100.00
Issuance Date: 12/06/2016
Nr Instances: 2
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0111100
Contest Date: 12/29/2016
Final Order: 01/22/2018
Related Event Code (REC):
Emphasis:
Substance: 0689
Substance: 0691
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/22/2018 | $2,100.00 | Serious | ||
Penalty | C: Contested | 01/03/2017 | $11,224.00 | Serious | ||
Penalty | Z: Issued | 12/06/2016 | $11,224.00 | Serious |
Text For Citation: 01 Item/Group: 010 Hazard:
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): Maintenance Garage - An initial chromium (VI) exposure determination was not made for workers who perform welding with stainless steel rods on stainless steel.