Violation Detail
Standard Cited: 19261101 J01 I Asbestos
Inspection Nr: 1001669.015
Citation: 01010
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $4,500.00
Issuance Date: 02/05/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/18/2015
Gravity: 10
Report ID: 0214200
Contest Date: 03/09/2015
Final Order: 08/03/2015
Related Event Code (REC):
Emphasis:
Substance: 9933
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/03/2015 | $4,500.00 | 02/18/2015 | Serious | |
Penalty | C: Contested | 03/13/2015 | $7,000.00 | 02/18/2015 | Serious | |
Penalty | Z: Issued | 02/05/2015 | $7,000.00 | 02/18/2015 | Serious |
Text For Citation: 01 Item/Group: 010 Hazard:
29 CFR 1926.1101(j)(1)(i): The employer did not establish a decontamination area, consisting of an equipment room, shower area, and clean room in series, adjacent and connected to the regulated area: a) 168 Elizabeth Ave., Newark, NJ - 3rd floor The employer did not provide or require the use of a decontamination area for employees performing dry removal of approximately 80 linear feet of thermal systems insulation (TSI) from overhead piping. The insulation was found to contain up to 80% Chrysotile asbestos. Conditions occurred on or about 9/24/2014 Note: This requirement applies to Class I operations involving over 25 linear or 10 square feet of thermal system insulation or surfacing containing asbestos-containing material or presumed asbestos-containing material.