Violation Detail
Standard Cited: 19100146 I07 Permit-required confined spaces
Inspection Nr: 977916.015
Citation: 01009B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/18/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 04/17/2015
Gravity: 10
Report ID: 0524530
Contest Date: 12/10/2014
Final Order: 05/11/2015
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/11/2015 | $0.00 | 04/17/2015 | Serious | |
| Penalty | C: Contested | 12/12/2014 | $0.00 | 12/01/2014 | Serious | |
| Penalty | Z: Issued | 11/18/2014 | $0.00 | 12/01/2014 | Serious |
Text For Citation: 01 Item/Group: 009B Hazard:
29 CFR 1910.146(i)(7): The employer did not ensure that each attendant summoned rescue and other emergency services as soon as the attendant determined that authorized entrants needed assistance to escape from permit space hazards: On or about May 20, 2014, on the Fuel side, employees were required to enter permit required confined space (ADMX 29425) to remove sweet crude oil. The Fuel side Entry Supervisor and Attendant did not summon outside local emergency rescue services, '911', when it was immediately determined that employee emergency responders could not remove the incapacitated Entrant.