Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1641755.015
Citation: 01009B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/04/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/30/2023
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 05/31/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 10/31/2023 | $0.00 | 11/30/2023 | Serious | |
Penalty | P: Petition to Mod Abatement | 10/10/2023 | $0.00 | 11/30/2023 | Serious | |
Penalty | I: Informal Settlement | 05/31/2023 | $0.00 | 07/31/2023 | Serious | |
Penalty | Z: Issued | 05/04/2023 | $0.00 | 05/22/2023 | Serious |
Text For Citation: 01 Item/Group: 009B Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; Employees working near 4-way notcher's auger were exposed to caught in hazards, in that the employer failed to guard the top pulley located 63" above walking working surface.