Violation Detail
Standard Cited: 19100212 A04 General requirements for all machines.
Inspection Nr: 1619294.015
Citation: 01009B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/10/2023
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 5
Report ID: 0112000
Contest Date: 02/06/2023
Final Order: 04/05/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/05/2023 | $0.00 | Serious | ||
Penalty | C: Contested | 02/06/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 01/10/2023 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 009B Hazard:
29 CFR 1910.212(a)(4): Revolving drum(s), barrel(s), or container(s) were not guarded by enclosure(s) which were interlocked with the drive mechanism so that the barrel(s), drum(s), or container(s) could not revolve unless the enclosure(s) were in place: North Building, Urethane Department: On, or about, October 6, 2022, the horizontal barrel mixer was not provided with safeguarding.