Violation Detail
Standard Cited: 19260062 J02 I A Lead
Inspection Nr: 1245184.015
Citation: 01009B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/22/2017
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 05/29/2019
Gravity: 5
Report ID: 0524200
Contest Date: 01/12/2018
Final Order: 04/29/2019
Related Event Code (REC):
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/29/2019 | $0.00 | 05/29/2019 | Serious | |
Penalty | C: Contested | 02/22/2018 | $0.00 | 01/29/2018 | Serious | |
Penalty | Z: Issued | 12/22/2017 | $0.00 | 01/29/2018 | Serious |
Text For Citation: 01 Item/Group: 009B Hazard:
29 CFR 1926.62(j)(2)(i)(A): The employer did not make available biological monitoring in the form of blood sampling and analysis for lead and zinc protoporphyrin levels to each employee covered under 29 CFR 1926.62(j)(1)(ii), at least every 2 months for the first 6 months and every 6 months thereafter: a) On July 6, 2017, American Demolition Corporation did not make available to each employee who was exposed to lead above the action level for more than 30 days in any consecutive 12 months, biological monitoring in the form of blood sampling and analysis for lead and zinc protoporphyrin levels at least every 2 months for the first 6 months and every 6 months thereafter. Employee(s) performing torch cutting operations were exposed to airborne lead levels exceeding the Permissible Exposure Limit.