Violation Detail
Standard Cited: 19101025 I04 II Lead.
Inspection Nr: 1108994.015
Citation: 01009B
Citation Type: Serious
Abatement Date: 03/03/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/24/2016
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0215800
Contest Date: 06/16/2016
Final Order: 11/14/2016
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/14/2016 | $0.00 | 03/03/2017 | Serious | |
Penalty | C: Contested | 06/16/2016 | $0.00 | 06/26/2016 | Serious | |
Penalty | Z: Issued | 05/24/2016 | $0.00 | 06/26/2016 | Serious |
Text For Citation: 01 Item/Group: 009B Hazard:
29 CFR 1910.1025(i)(4)(ii): Lunchroom facilities for employees exposed to lead in excess of the permissible exposure limit (PEL), without regard to the use of respirators, were not provided with a temperature controlled, positive pressure, filtered air supply: a) Patco Area, Strip and Wash Building, on or about 12/1/15: An employee MIG welding the undercarriage of a rail car was exposed to 173 micrograms per cubic meter of lead as an 8-hr. time weighted average (TWA), 3.5 times the permissible exposure limit (PEL) of 50 micrograms per cubic meter, during the 415 minute sampling period. A zero increment was included for the 65 minutes not sampled. The employer failed to provide a lunch room with positive pressure. Abatement documentation must be submitted for this item