Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1073479.015
Citation: 01009B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/10/2015
Nr Instances: 2
Nr Exposed: 5
Abatement Date: 12/22/2015
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 01/11/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/11/2016 | $0.00 | 12/22/2015 | Serious | |
Penalty | Z: Issued | 12/10/2015 | $0.00 | 12/22/2015 | Serious |
Text For Citation: 01 Item/Group: 009B Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains that were seven (7) or less feet from the floor or platform were not enclosed: (a) Big Dipper: On or about June 25, 2015, and times prior, employees work near and around the chain powered by 440V, 3 phase electric power that is not provided with a guard on the top of the trough or in the control area where the chain is less than 7 feet from the floor and unprotected on all sides. (b) Little Dipper: On or about June 25, 2015, and times prior, employees work near and around the chain powered by 240V, 3 phase electric power is not provided with a guard on the top of the trough. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM