Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 989172.015
Citation: 01009A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,000.00
Current Penalty: $3,400.00
Issuance Date: 01/28/2015
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 02/09/2015
Gravity: 5
Report ID: 0626300
Contest Date: 02/24/2015
Final Order: 10/16/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 10/16/2015 | $3,400.00 | 02/09/2015 | Serious | |
Penalty | C: Contested | 02/27/2015 | $2,000.00 | 02/09/2015 | Serious | |
Penalty | Z: Issued | 01/28/2015 | $2,000.00 | 02/09/2015 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.219(d)(1): Pulleys, with any part seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in 29 CFR 1910.219 paragraphs (m) and (o): The employer does not ensure that pulleys with parts seven feet or less above floors or platforms are guarded. This violation occurred on or about August 5, 2014, and at times prior thereto; where: a) In the grinding area, the pulleys to a homemade fan were not guarded and exposed employees to in-going nip points.