Violation Detail
Standard Cited: 19100219 B01 Mechanical power-transmission apparatus.
Inspection Nr: 1641755.015
Citation: 01009A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,688.00
Current Penalty: $2,344.00
Issuance Date: 05/04/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/30/2023
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 05/31/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 10/31/2023 | $2,344.00 | 11/30/2023 | Serious | |
Penalty | P: Petition to Mod Abatement | 10/10/2023 | $2,344.00 | 10/31/2023 | Serious | |
Penalty | I: Informal Settlement | 05/31/2023 | $2,344.00 | 07/31/2023 | Serious | |
Penalty | Z: Issued | 05/04/2023 | $4,688.00 | 05/22/2023 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.219(b)(1):Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv) a) Center Manufacturing Company, on or about December 14, 2022, at the address of 540 Goodrich Rd. Bellevue, OH; The employer failed to ensure the 11" flywheel located at the end of the 4-way notcher's auger was adequately guarded. Employees performing work tasks in proximity of the unguarded flywheel were exposed to caught in hazards.