Violation Detail
Standard Cited: 19100252 C01 III General requirements.
Inspection Nr: 1251555.015
Citation: 01009A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,434.00
Current Penalty: $800.00
Issuance Date: 01/08/2018
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/11/2019
Gravity: 5
Report ID: 0524530
Contest Date: 02/02/2018
Final Order: 02/11/2019
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/11/2019 | $800.00 | 04/11/2019 | Serious | |
Penalty | C: Contested | 02/06/2018 | $4,434.00 | 02/02/2018 | Serious | |
Penalty | Z: Issued | 01/08/2018 | $4,434.00 | 02/02/2018 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.252(c)(1)(iii): Local exhaust or general ventilating systems were not provided and arranged to keep the amount of toxic fumes, gases, or dusts below the maximum allowable concentration as specified in 29 CFR 1910.1000: The employer did not ensure that adequate local or general dilution exhaust systems were provided to keep the amount of welding fumes and metals dusts below the permissible exposure limit as specified in 29 CFR 1910.1000. On or about October 4th, 2017, an employee was exposed to an 8-hour time weighted average of 0.117 mg/m3 for Copper fume.