Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1219927.015
Citation: 01009A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,897.00
Current Penalty: $1,883.00
Issuance Date: 09/06/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/04/2017
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 09/29/2017
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/29/2017 | $1,883.00 | 10/04/2017 | Serious | |
Penalty | Z: Issued | 09/06/2017 | $2,897.00 | 10/04/2017 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). The side panel exposing the belt and pulley to the Bridgeport Drill press was not guarded, exposing employees to ingoing nip point hazards.