Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1212211.015
Citation: 01009A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,605.00
Current Penalty: $4,563.00
Issuance Date: 03/30/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/10/2017
Gravity: 5
Report ID: 0625400
Contest Date:
Final Order: 05/01/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/01/2017 | $4,563.00 | 04/10/2017 | Serious | |
Penalty | Z: Issued | 03/30/2017 | $7,605.00 | 04/10/2017 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): On or about February 21, 2017, in building 2, the Ridgid table saw was being used by employees to cut styrofoam sheets without the belt being guarded. Employees exposed to the hazard of being caught-in the rotating belt.