Violation Detail
Standard Cited: 19101025 I02 I Lead.
Inspection Nr: 1108994.015
Citation: 01009A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $5,950.00
Issuance Date: 05/24/2016
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 10/15/2016
Gravity: 10
Report ID: 0215800
Contest Date: 06/16/2016
Final Order: 11/14/2016
Related Event Code (REC):
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/14/2016 | $5,950.00 | 10/15/2016 | Serious | |
Penalty | C: Contested | 06/16/2016 | $7,000.00 | 06/26/2016 | Serious | |
Penalty | Z: Issued | 05/24/2016 | $7,000.00 | 06/26/2016 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.1025(i)(2)(i): Clean change rooms were not provided for employees exposed to lead in excess of the permissible exposure limit (PEL), without regard to the use of respirators: a) Patco Area, Strip and Wash Building, on or about 12/1/15: An employee MIG welding the undercarriage of a rail car was exposed to 173 micrograms per cubic meter of lead as an 8-hr. time weighted average (TWA), 3.5 times the permissible exposure limit (PEL) of 50 micrograms per cubic meter, during the 415 minute sampling period. A zero increment was included for the 65 minutes not sampled. The employer failed to provide change rooms with shower facilities for employees exposed to lead in excess of the PEL. Abatement documentation must be submitted for this item