Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1073479.015
Citation: 01009A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,200.00
Current Penalty: $2,520.00
Issuance Date: 12/10/2015
Nr Instances: 3
Nr Exposed: 10
Abatement Date: 12/22/2015
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 01/11/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/11/2016 | $2,520.00 | 12/22/2015 | Serious | |
Penalty | Z: Issued | 12/10/2015 | $4,200.00 | 12/22/2015 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Maintenance Shop: On or about June 25, 2015, and times prior, employees use and work around an industrial floor fan measuring 75 inches wide by 60 inches in height that was not provided with a guard on the backside to cover the pulley that was 21 inches from the floor. (b) Maintenance Shop: On or about June 25, 2015, and times prior, employees use and work around a compressor that was not provided with a guard to cover the pulley that was 25 inches from the floor. (c) Big Dipper: On or about June 25, 2015, and times prior, maintenance employees work in the control area where a guard was not provided to cover the pulley that was 24 inches from the ground. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM