Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 983761.015
Citation: 01009
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $3,000.00
Current Penalty: $3,000.00
Issuance Date: 01/07/2015
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 01/18/2016
Gravity:
Report ID: 0729700
Contest Date: 01/21/2015
Final Order: 02/29/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/29/2016 | $3,000.00 | 01/18/2016 | Other | |
Penalty | C: Contested | 01/29/2015 | $3,000.00 | 01/30/2015 | Serious | |
Penalty | Z: Issued | 01/07/2015 | $3,000.00 | 01/30/2015 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: The rotating shafts on the flash-card for the condenser pumps were not covered by a wire mesh to protect employees from caught-in hazards caused by rotating parts. 29 CFR 1903.19(d)(1) requires certification that the abatement of the above violation is completed.