Violation Detail
Standard Cited: 19100119 J04 II Process safety management of highly hazardous chemicals.
This violation item has been deleted.
Inspection Nr: 313137804
Citation: 01009
Citation Type: Serious
Abatement Status:
Initial Penalty: $7,000.00
Current Penalty:
Issuance Date: 09/14/2011
Nr Instances: 1
Nr Exposed: 500
Abatement Date: 09/27/2011
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order:
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/28/2011 | 09/27/2011 | Serious | ||
| Penalty | Z: Issued | 09/14/2011 | $7,000.00 | 09/27/2011 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard: CHEMNEP
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity, did not follow recognized and generally accepted good engineering practices: The employer did not follow recognized and generally accepted good engineering practices when they pressure-tested the piping on the glycol chiller control unit piping with anhydrous ammonia gas. ABATEMENT DOCUMENTATION REQUIRED PER 29 CFR 1903.19(d)ION