Violation Detail
Standard Cited: 19100179 M01 Overhead and gantry cranes.
Inspection Nr: 1744068.015
Citation: 01009
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,098.25
Issuance Date: 10/23/2024
Nr Instances: 1
Nr Exposed: 42
Abatement Date: 12/20/2024
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 11/19/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/19/2024 | $12,098.25 | 12/20/2024 | Serious | |
Penalty | Z: Issued | 10/23/2024 | $16,131.00 | 11/19/2024 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.179(m)(1):A certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier for the ropes which were inspected were not being kept on file where readily available to appointed personnel: (a) Metal Fabrication Area: on or about and at times prior to April 24, 2024, employees operated a 15/5-ton Shaw Box S/N # 38783, to hoist, move and reposition steel transformer housings weighing up to 15-tons. There were multiple kinks in the wire ropes near the upper block and hoist drum.