Violation Detail
Standard Cited: 19100217 C03 VII D Mechanical power presses.
Inspection Nr: 1733864.015
Citation: 01009
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $7,000.00
Issuance Date: 06/21/2024
Nr Instances: 11
Nr Exposed: 14
Abatement Date: 04/30/2025
Gravity: 10
Report ID: 0627500
Contest Date: 07/17/2024
Final Order: 04/30/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/30/2025 | $7,000.00 | 04/30/2025 | Serious | |
Penalty | C: Contested | 07/18/2024 | $11,292.00 | 07/03/2024 | Serious | |
Penalty | Z: Issued | 06/21/2024 | $11,292.00 | 07/03/2024 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.217(c)(3)(vii)(d): Two hand controls used with mechanical power press(es) were not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls: a) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Stamtec Punch Press #56 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. b) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Stamtec Punch Press #57 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. c) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Stamtec Punch Press #58 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. d) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Stamtec Punch Press #32 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. e) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Stamtec Punch Press #33 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. f) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Stamtec Punch Press # 34 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. g) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Warco Punch Press #59 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. h) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Reevis Punch Press #54 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. i) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Bliss Punch Press #112 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated. j) On or about March 13, 2024, and at times prior thereto, EPTD and Stamtec press areas; employee(s) operating the Bliss Punch Press #119 two hand trip device was not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls while the machine was operated.