Violation Detail
Standard Cited: 19261052 B01 Stairways.
Inspection Nr: 1621917.015
Citation: 01009
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $3,572.00
Current Penalty: $1,800.00
Issuance Date: 03/13/2023
Nr Instances: 1
Nr Exposed: 8
Related Event Code (REC):
Gravity: 5
Report ID: 0215000
Contest Date:
Final Order: 04/12/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/12/2023 | $1,800.00 | Serious | ||
Penalty | Z: Issued | 03/13/2023 | $3,572.00 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1926.1052(b)(1):Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. Location: 930 58th Street, Brooklyn, NY 11219 On or about: September 14, 2022 (a) The treads of the stairway leading to the roof level was not temporarily filled or fitted with wood or equivalent solid material at least to the top edge of each pan; employees used the stairway to access the roof level to perform masonry and welding.