Violation Detail

Standard Cited: 19100303 F02 General.

Inspection Nr: 1608381.015

Citation: 01009

Citation Type: Serious

Abatement Status: Not Completed - Employer Out of Business

Initial Penalty: $7,977.00

Current Penalty: $7,977.00

Issuance Date: 01/12/2023

Nr Instances: 9

Nr Exposed: 33

Abatement Date: 02/23/2023

Gravity: 5

Report ID: 1032100

Contest Date: 02/09/2023

Final Order: 08/07/2023

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty J: ALJ Decision 08/07/2023 $7,977.00 02/23/2023 Serious  
Penalty C: Contested 02/09/2023 $7,977.00 02/23/2023 Serious  
Penalty Z: Issued 01/12/2023 $7,977.00 02/23/2023 Serious  

Text For Citation: 01 Item/Group: 009 Hazard:

29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Wheelhouse/Breaker 3 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. b) Wheelhouse/Breaker 4 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. c) Wheelhouse/Breaker 16 - On or about July 20, 2022, and times prior thereto, a 60 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. d) Wheelhouse/Breaker 20 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in electrical panel labeled Wheel House Fuse Box. The circuit breaker was not labeled to indicate its purpose nor was it arranged so the purpose was evident, exposing employees to electrical hazards. e) Laundry Room/Breaker 19 - On or about July 20, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in the on position in an electrical panel. The circuit breaker was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards. f) Forward Cold Storage/Breakers Throughout - On or about September 29, 2022, and times prior thereto, circuit breakers were observed without labeling to indicate their purpose nor were they arranged so the purpose was evident, exposing employees to electrical hazards. g) Engine Room/Breaker 14 - On or about October 2, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in the on position in an electrical panel. The circuit breaker was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards. h) Stateroom 8/Breaker 11 - On or about October 25, 2022, and times prior thereto, a 20 AMP circuit breaker was observed in the on position in an electrical panel. The circuit breaker was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards. i) Stateroom 8/Breaker 20 - On or about October 25, 2022, and times prior thereto, a 20 AMP circuit breaker was observed installed in an electrical panel and was not labeled to indicate its purpose and was not arranged so the purpose was evident, exposing employees to electrical hazards.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.