Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1605724.015
Citation: 01009
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,151.00
Current Penalty: $5,075.50
Issuance Date: 12/14/2022
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 01/11/2023
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 01/10/2023
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/10/2023 | $5,075.50 | 01/11/2023 | Serious | |
Penalty | Z: Issued | 12/14/2022 | $10,151.00 | 01/11/2023 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.219(f)(1):Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a.) At 454 Park St, Sebring, FL: On or about 06/23/2022, the employer exposed employees to amputation hazards, in that the truss press machine chains and sprockets are not guarded while machine is in operation