Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1488569.015
Citation: 01009
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,901.00
Current Penalty: $2,300.00
Issuance Date: 02/10/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/05/2021
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 03/05/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/05/2021 | $2,300.00 | 03/05/2021 | Serious | |
Penalty | Z: Issued | 02/10/2021 | $3,901.00 | 03/05/2021 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Manufacturing Warehouse - On or about August 14, 2020 the belt and pulley that drive the mixer's motor were not guarded from accidental contact, exposing employees to amputation hazards.