Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1462822.015
Citation: 01009
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $5,783.00
Current Penalty: $2,891.50
Issuance Date: 04/17/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 1
Report ID: 0418800
Contest Date:
Final Order: 04/30/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/30/2020 | $2,891.50 | Serious | ||
Penalty | Z: Issued | 04/17/2020 | $5,783.00 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about 2/6/2020, at outside of east side mill of Sugar Cane Growers Cooperative of Florida, 1500 George Wedgworth Way, Belle Glade, FL 33430, employees were exposed to a caught by hazard while permitted to do housekeeping near and around an unprotected rotating shaft.