Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1151352.015
Citation: 01009
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $6,600.00
Issuance Date: 12/09/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 11/09/2018
Gravity: 10
Report ID: 0728500
Contest Date: 12/27/2016
Final Order: 01/10/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 01/10/2018 | $6,600.00 | 11/09/2018 | Serious | |
| Penalty | C: Contested | 01/25/2017 | $0.00 | 01/13/2017 | Serious | |
| Penalty | Z: Issued | 12/09/2016 | $0.00 | 01/13/2017 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) On or about July 7, 2016, the employer failed to instruct affected employees in the purpose and use of the energy control procedure. Employees working in the fittings department are exposed to caught in and electric shock hazards in that affected employees have not received training/instruction related to energy control procedures pertaining to the Elbow Machines, and automatic and manual Iowa Precision Collar Machines and/or awareness of those procedures. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Translate