Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1007955.015
Citation: 01009
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,900.00
Current Penalty: $4,500.00
Issuance Date: 05/01/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/28/2015
Gravity: 10
Report ID: 0729300
Contest Date: 05/22/2015
Final Order: 12/21/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 12/21/2015 | $4,500.00 | 10/28/2015 | Serious | |
| Penalty | C: Contested | 05/22/2015 | $4,900.00 | 06/18/2015 | Serious | |
| Penalty | Z: Issued | 05/01/2015 | $4,900.00 | 06/18/2015 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operattion (P.O.O.) of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycles: a/ Transformer Department (lower level of facility at 4328 Bridgeton Industrial Park Drive, Bridgeton, MO 63044): The P.O.O. belonging to the T & B Crimper Machine, m/n C13600, s/n 1602PP37705, was unguarded. The opening of the die belonging to this machine was approximately one inch.