Violation Detail
Standard Cited: 19100305 J01 II Wiring methods, components, and equipment for general use.
Inspection Nr: 1663504.015
Citation: 01008C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,250.00
Current Penalty: $0.00
Issuance Date: 09/22/2023
Nr Instances: 5
Nr Exposed: 10
Abatement Date: 10/19/2023
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 10/18/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/18/2023 | $0.00 | 10/19/2023 | Serious | |
| Penalty | Z: Issued | 09/22/2023 | $6,250.00 | 10/19/2023 | Serious |
Text For Citation: 01 Item/Group: 008C Hazard:
29 CFR 1910.305(j)(1)(ii): Portable hand-lamps supplied through flexible cords were not equipped with a handle of molded composition or other material approved for the purpose, and a substantial guard attached to the lamp-holder or the handle: a) Operations Area - The employer provided four portable hand lamps with a metal shell, non-insulated handles, and without a guard for employees to use when illumination was needed on each of the four V&O full revolution mechanical power presses, numbered one through four. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).