Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1763543.015
Citation: 01008B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,610.00
Current Penalty: $1,000.00
Issuance Date: 11/05/2024
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 11/12/2024
Gravity: 5
Report ID: 0626600
Contest Date: 01/03/2025
Final Order: 04/14/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/14/2025 | $1,000.00 | 11/12/2024 | Serious | |
Penalty | C: Contested | 01/07/2025 | $4,610.00 | 11/12/2024 | Serious | |
Penalty | Z: Issued | 11/05/2024 | $4,610.00 | 11/12/2024 | Serious |
Text For Citation: 01 Item/Group: 008B Hazard:
29 CFR 1910.212(a)(5):Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: On or about July 23, 2024, at the shop employees were using a large box fan that had gaps in the front guard and a missing rear guard exposing the fan blades.