Violation Detail
Standard Cited: 19100212 A02 General requirements for all machines.
Inspection Nr: 1617134.015
Citation: 01008B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,256.00
Current Penalty: $0.00
Issuance Date: 01/04/2023
Nr Instances: 4
Nr Exposed: 7
Abatement Date: 07/31/2024
Gravity: 5
Report ID: 0521100
Contest Date: 01/31/2023
Final Order: 06/12/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/12/2023 | $0.00 | 07/31/2024 | Serious | |
Penalty | C: Contested | 02/03/2023 | $10,256.00 | 02/02/2023 | Serious | |
Penalty | Z: Issued | 01/04/2023 | $10,256.00 | 02/02/2023 | Serious |
Text For Citation: 01 Item/Group: 008B Hazard:
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. On or about August 24, 2022, at an establishment located at 605 Washington Street, in Manitowoc, Wisconsin, in Malt House 6 on the Germ Bed Compartment 2; at the front of the germ bed, the horizontal auger which fed into the in-floor auger had a hinged guard which was not securely attached allowing access to the rotating auger, exposing employees to entanglement hazards.