Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1505846.015
Citation: 01008B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/09/2021
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 09/10/2021
Gravity: 5
Report ID: 0418200
Contest Date:
Final Order: 07/01/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/01/2021 | $0.00 | 09/10/2021 | Serious | |
Penalty | Z: Issued | 06/09/2021 | $0.00 | 07/06/2021 | Serious |
Text For Citation: 01 Item/Group: 008B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Facility-wide : On or about 12/11/2020, the employer exposed employees to struck-by and caught-in hazards in that the employer did not adequately provide either authorized or affected employee training before employees performed servicing or maintenance on the dock plate, cut table and inspection table.