Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1063115.015
Citation: 01008B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/28/2015
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 08/13/2015
Gravity: 5
Report ID: 0524700
Contest Date: 08/21/2015
Final Order: 04/13/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/13/2016 | $0.00 | 08/13/2015 | Serious | |
Penalty | C: Contested | 08/26/2015 | $0.00 | 08/13/2015 | Serious | |
Penalty | Z: Issued | 07/28/2015 | $0.00 | 08/13/2015 | Serious |
Text For Citation: 01 Item/Group: 008B Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a. Wilbert, Inc. - Bellevue, OH: On or about May 14, 2015, the employer did not ensure that lockout devices were affixed to the robot associated with press A56 before employees changed the press mold. A potential for unexpected startup of the robot existed while employees performed mold changing operations.