Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1047229.015
Citation: 01008B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/29/2015
Nr Instances: 1
Nr Exposed: 50
Abatement Date: 08/04/2015
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 08/19/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/19/2015 | $0.00 | 08/04/2015 | Serious | |
Penalty | Z: Issued | 07/29/2015 | $0.00 | 08/04/2015 | Serious |
Text For Citation: 01 Item/Group: 008B Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: a. Heat treatment oven, employees were exposed to a struck by hazard, in that, guards were not installed to protect employees from the rotating fan blades used to circulate the air inside the oven after an interlock at the door was broken and disabled, on or about 03/18/2015.