Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1044858.015
Citation: 01008B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/02/2015
Nr Instances: 40
Nr Exposed: 4
Abatement Date: 09/24/2015
Gravity: 10
Report ID: 0626000
Contest Date:
Final Order: 10/01/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/01/2015 | $0.00 | 09/24/2015 | Serious | |
| Penalty | Z: Issued | 09/02/2015 | $0.00 | 09/24/2015 | Serious |
Text For Citation: 01 Item/Group: 008B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven (7) feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: On or before March 6, 2015, for each of the forty (40) lanes at this location, employees were exposed to unguarded horizontal belts on pin setting machines that were located fifty-six (56) inches above the floor.