Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 998318.015
Citation: 01008A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $2,000.00
Issuance Date: 04/01/2015
Nr Instances: 5
Nr Exposed: 10
Abatement Date: 05/06/2016
Gravity: 10
Report ID: 0213100
Contest Date: 04/23/2015
Final Order: 01/06/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 01/06/2016 | $2,000.00 | 05/06/2016 | Serious | |
Penalty | C: Contested | 05/07/2015 | $2,800.00 | 05/18/2015 | Serious | |
Penalty | Z: Issued | 04/01/2015 | $2,800.00 | 05/18/2015 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.147(c)(1): Respondent does not have a lock-out/tag-out program for equipment such as but not limited to A Bank and B Bank tumblers, Lathe 1 and 2, Drill Presses 1,2,3, and 4, centerless grinders, and Cup Machine in the tumbler room and the drill press room.