Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 905368.015
Citation: 01008A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $1,400.00
Issuance Date: 08/19/2013
Nr Instances: 5
Nr Exposed: 3
Abatement Date: 10/04/2013
Gravity: 5
Report ID: 0111500
Contest Date:
Final Order: 09/13/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/13/2013 | $1,400.00 | 10/04/2013 | Serious | |
| Penalty | Z: Issued | 08/19/2013 | $2,800.00 | 10/04/2013 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. WORKSHOP: The horizontal shafts of the following Brown & Sharpe milling machines in Cell 3 were partially unguarded: 1. Cell 3 Brown & Sharpe mill, had partially unguarded horizontal shafts. 2. Cell 3 Brown & Sharpe mill, #1 ID 8375, horizontal shaft partially unguarded. 3. Brown & Sharpe mill, R/C 9/77, horizontal shaft partially unguarded. 4. Cell 3, partially unguarded horizontal shaft. 5. #5 Cell 3, Brown & Sharpe mill, partially unguarded horizontal shaft.