Violation Detail
Standard Cited: 19101000 A02 Air contaminants.
This violation item has been deleted.
Inspection Nr: 1400452.015
Citation: 01008A
Citation Type: Serious
Abatement Status:
Initial Penalty: $9,472.00
Current Penalty: $0.00
Issuance Date: 11/13/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 12/18/2019
Gravity: 5
Report ID: 0215800
Contest Date: 11/21/2019
Final Order: 10/14/2021
Related Event Code (REC):
Emphasis:
Substance: 1520
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 10/14/2021 | $0.00 | 12/18/2019 | Serious | |
| Penalty | C: Contested | 11/22/2019 | $9,472.00 | 12/18/2019 | Serious | |
| Penalty | Z: Issued | 11/13/2019 | $9,472.00 | 12/18/2019 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Iron Oxide Fume listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 10 mg/m3: a) Grinding Court Yard, on or about 8/15/19: A maintenance employee changing out the Grinding Dust Collector filters was exposed to 10.96 milligrams per cubic meter (mg/m3) of iron oxide fume, eight hour time weighted average (TWA), approximately 1.10 times the OSHA permissible exposure limit of 10.0 mg/m3. The sampling period was for 84 minutes. A zero increment is included for the 396 minutes not sampled. Employee was wearing a P100 Filtering Face Piece. b) Grinding Court Yard, on or about 8/15/19: A maintenance employee changing out the Grinding Dust Collector filters was exposed to 14.72 milligrams per cubic meter (mg/m3) of iron oxide fume, eight hour time weighted average (TWA), approximately 1.47 times the OSHA permissible exposure limit of 10.0 mg/m3. The sampling period was for 89 minutes. A zero increment is included for the 391 minutes not sampled. Employee was wearing a P100 Filtering Face Piece.
Translate