Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1374883.015
Citation: 01008A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,347.00
Current Penalty: $2,820.00
Issuance Date: 05/31/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/26/2019
Gravity: 1
Report ID: 0418100
Contest Date:
Final Order: 07/02/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/02/2019 | $2,820.00 | 06/26/2019 | Serious | |
Penalty | Z: Issued | 05/31/2019 | $4,347.00 | 06/26/2019 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Garick, LLC, Cumming, GA - In the bulk mill, oxygen and acetylene cylinders were stored next to entry door of the electrical room and not secured, on or about 1/30/19. b) Garick, LLC, Cumming, GA - In the bulk mill, an oxygen cylinder was stored leaning against the outside wall of the electrical room, on or about 1/30/19.