Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1336566.015
Citation: 01008A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,304.00
Current Penalty: $1,617.10
Issuance Date: 02/05/2019
Nr Instances: 1
Nr Exposed: 8
Abatement Date:
Gravity: 10
Report ID: 0215000
Contest Date: 03/04/2019
Final Order: 03/05/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/05/2020 | $1,617.10 | Serious | ||
Penalty | C: Contested | 03/18/2019 | $5,304.00 | Serious | ||
Penalty | Z: Issued | 02/05/2019 | $5,304.00 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o) Location: 5401 1st Ave Brooklyn NY On or about: August 07, 2018 a) Exposed pulley on the motor of the cutter machine not guarded.