Violation Detail
Standard Cited: 19261101 K03 I Asbestos
Inspection Nr: 1323592.015
Citation: 01008A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,691.00
Current Penalty: $3,750.00
Issuance Date: 09/27/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/10/2018
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 10/16/2018
Related Event Code (REC): R
Emphasis:
Substance: 9020
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/16/2018 | $3,750.00 | 10/10/2018 | Serious | |
Penalty | Z: Issued | 09/27/2018 | $5,691.00 | 10/10/2018 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1926.1101(k)(3)(i): Before the employer permitted its own employees to perform work subject to this standard in areas containing asbestos-containing material (ACM) and presumed asbestos-containing material (PACM), the employer did not identify the presence, location and quantity of asbestos containing material and/or presumed asbestos containing material therein pursuant to 29 CFR 1926.1101(k)(1): a) Advanced Construction and Design Services, LLC: On or about April 11-12, 2018, at the jobsite located at 1650 W. Irving Park Rd. Chicago, Illinois, the employer did not identify the presence, location, and quantity of ACM and PACM prior to employees performing demolition work including removal of thermal system insulation containing 18-35% chrysotile asbestos.