Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1105288.015
Citation: 01008A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $3,500.00
Issuance Date: 04/28/2016
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 06/17/2016
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 05/23/2016
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/23/2016 | $3,500.00 | 06/17/2016 | Serious | |
Penalty | Z: Issued | 04/28/2016 | $5,000.00 | 06/17/2016 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Blue line; On or before November 09, 2015, the employer did not guard exposed horizontal shafts used as drive mechanisms for the production line.