Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1104919.015
Citation: 01008A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $3,500.00
Current Penalty: $1,782.00
Issuance Date: 05/06/2016
Nr Instances: 7
Nr Exposed: 20
Abatement Date: 12/29/2017
Gravity:
Report ID: 0522500
Contest Date: 05/18/2016
Final Order: 10/16/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/16/2017 | $1,782.00 | 12/29/2017 | Other | |
Penalty | C: Contested | 05/26/2016 | $3,500.00 | 05/26/2016 | Serious | |
Penalty | Z: Issued | 05/06/2016 | $3,500.00 | 05/26/2016 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a. In the grain handling department the intersystem conveyor head had 2 inches of exposed shaft, thereby exposing employees to a caught in hazard. b. In the grain department the DDGS reclaim elevator motor had two unguarded shafts the 2 inches at five feet and 4 inches at 6 feet, thereby exposing employees to a caught in hazard. c. In the DD&E building there were 6 inadequately guarded pump motors with 3 inches of horizontal shafting each, thereby exposing employees to a caught in hazard. d. In the tank farm there were four pump motors with 2 inches of unguarded horizontal shaft each, thereby exposing employees to a caught in hazard.